Running Calibrations
Use Workflow for a repeatable sequence of tasks, or use Tasks to run one calibration task against a selected qubit or coupling.
Both routes use the active project and chip. Confirm both before starting because a run can update the calibration values used by later tasks.
Choose a Run Mode
| Goal | Start from |
|---|---|
| Run a saved task graph or schedule | Workflow |
| Run one task and inspect its result immediately | Tasks |
| Repeat a previous run with selected values restored | The source execution or task result |
Running a workflow or task requires project edit permission.
Run a Workflow
- Open Workflow and select a workflow. Follow Creating Workflows first if you need to create or change one.
- Select Edit before changing the source, then select Save.
- Select Execute.
- Review the flow name, username, chip, and tags in the confirmation dialog.
- Under Calibration targets, review the defaults from the saved workflow. To change them for this run, select MUX IDs or Qubit IDs and enter IDs separated by commas or spaces. For MUX targets, use Excluded qubit IDs to omit individual qubits.
- Confirm the run, then open Execution to follow its progress.
Leaving the target fields unchanged preserves the workflow's code settings. Use code defaults discards target edits. An explicit change replaces the initial calibration targets throughout the current flow run; later filtering steps still apply. The saved workflow and schedules are unchanged. A workflow that targets all MUXes or couplings stops with an error when you change its targets.
If targets depend on runtime calculations or differ within the workflow, the dialog cannot show a single default. Leave the fields unchanged to use the code, or enter an explicit selection for the run. Separate nested workflow runs retain their own targets.
Use the workflow schedule panel when the same flow must run automatically. Manage schedules in QDash so the workflow and its Prefect deployment remain aligned.
Run One Task
- Open Tasks and select a task.
- Under Setup, select Chip and enter a Qubit or coupling such as
0or0-1. - Select Reload to check hardware availability and load the current input values.
- Review Input parameter overrides and Run parameters. Leave an input override blank to use the current calibration value.
- Enable Reconfigure hardware first when the current calibration configuration must be applied before the task starts.
- Enable Save calibrated outputs to DB only when successful outputs should become the current calibration values.
- Select Run task and follow the status in Results.
The run button stays disabled while another execution holds the same hardware or until Reload has checked a changed target. See Task Parameters before overriding inputs or saving outputs.
Monitor a Run
Open Execution to inspect a run's status, task topology, timing, parameters, output, and artifacts. Select a task in the topology to open its details, or select a node in the execution flow to preview its result in the same side panel that Task Results uses; open the full result from there. While a run is in progress, its details and its page show how many tasks have finished and which one is being measured, and the running task shows its measurement progress.
Cancelling a run sends a cancellation request to the worker. A task that is inside an operation that cannot be interrupted can take time to stop.
The activity chart at the top of the page counts the chip's runs for the last 7d, 30d or 90d as blocks stacked by status; it opens on 30 days. The 30- and 90-day views show one column per day (Executions per day). The 7-day view shows Executions per 6 hours: 28 columns that start at 00:00, 06:00, 12:00 and 18:00 in the deployment's time zone, ending with the 6 hours that include the current time. Days and periods without runs keep an empty column.
Each block represents one execution, and the axis on the left shows execution counts. For busy periods, the chart labels how many executions a full block represents; the top block of a column is only partly filled when it holds fewer. Hover over or focus a column to see its exact counts. Select a column to limit the list below to its day; in the 7-day view, a 6-hour column selects its whole day, because the list filters by day. Select a column of that day again to return to the latest runs.
Inspect a Result
Open Task Results when you know the chip, execution, task, target, or status you want to find. Open an item to inspect its effective parameters, figures, raw data, notes, and linked discussion.
Use an execution detail when the dependency graph matters. Use Task Results when one measurement or failure is the focus. See Reviewing and Sharing Results for the review workflow.
Edit Workflow Configuration
Open Config to edit the active project's Qubex configuration files. Save local changes before pulling or creating a pull request; pulling can replace the working copy.
Figures and raw data stay associated with the project, chip, execution, and task result that produced them. See Share and Hand Off a Result before handing a run over to another project member.