Skip to content

Task Calls ​

A TaskCall gives one task occurrence its own settings, identity, and results. Python flows and pipeline specs use the same model.

python
from qdash.calibration import CustomOneQubit, TaskCall

CustomOneQubit(
    step_name="ramsey",
    tasks=[
        TaskCall(name="Configure", on_failure="stop"),
        TaskCall(name="CheckRamsey", call_id="coarse", run={"detuning": 0.001}),
        TaskCall(name="CheckRamsey", call_id="fine", run={"detuning": 0.0002}),
    ],
)

Identity ​

IDScope
step_idUnique calibration step in a pipeline; custom steps use step_name
call_idUnique call in that step; defaults to the task name
task_idEngine-assigned result for one call on one target

Every occurrence of a repeated task needs an explicit call ID. Call IDs match ^[A-Za-z][A-Za-z0-9_.-]{0,63}$; step IDs match ^[a-z][a-z0-9_]{0,63}$. Results record invocation with the step, call, settings, and plan digest. Each execution stores the plan; recorded input and run snapshots remain the evidence of what actually ran.

Settings ​

Set run for experiment settings, input for allowed calibration overrides, and update_calibration_parameters=False for measurement-only output. Absent or None fields inherit. Calls override per-task defaults, shared run defaults, and task defaults in that order. Use plain input values and plain or sweep run values. Session constraints still apply; see Parameter Resolution.

Failure Policy ​

on_failure="stop" skips that target's remaining calls; "continue" runs them. An unset value inherits the step's continue_on_failure. One target's failure does not stop another target. Failed outputs do not replace accepted calibration values.

Scheduling ​

Ordinary targets run their complete call list independently. Round and step boundaries wait for all their targets. simultaneous_spectroscopy instead runs each call over a batch and rejects input overrides or tasks without batch support before measuring. MUX tasks run only on their representative qubit; other members record a skipped call.

Results ​

Use data.calls, data.call(call_id), or data.latest_call(name). Any failed call makes its target's step status failed. Built-in metrics use the last call of a task, never an earlier successful call in place of a failed last call.

Filters with step and call_id read that exact call; with only step, they read step status or metrics. Custom-step metric filters need a call ID. Without step, filters read the latest OneQubitFineTune or OneQubitCheck. Filters use this run's results, not current database values. Stored results can be queried by execution_id, step_id, and call_id.

Re-execution ​

Snapshot lookup matches task, target, step, and call. Legacy results without invocation metadata are usable only when unambiguous; otherwise lookup fails. Re-execution is not an idempotent retry.

Migrate Saved Flows ​

Back up saved flow sources before editing. QDash does not rewrite them automatically.

  1. Replace task-name strings with TaskCall(name=...); annotate task-list parameters as list[TaskCall] | None.
  2. Give repeated calls and steps distinct IDs.
  3. Replace stop_on_failure_tasks with on_failure="stop" on those calls.
  4. Move per-occurrence settings onto calls.
  5. Replace raw task-name result lookup with the call accessors above.
  6. Give filters explicit step/call references when they must select a particular result.

Test on the Fake backend and inspect call IDs and effective settings before hardware use. Older results remain readable without invocation.

Migrate per-task defaults ​

CalibService rejects task_parameters and task_run_parameters. Merge each task's old settings into every call of that task, preserving values already set on the call, including explicit True and False. Apply old task_run_parameters first, then task_parameters. Keep call IDs, order, and failure policies unchanged.

Shared run values can remain in default_run_parameters. A standalone step takes its own call, for example ConfigureAll(call=TaskCall(name="ConfigureAll", run={"configuration_mode": "ge-ef-cr"})). Its target-derived MUX IDs still override the call's run.mux_ids. Compare effective settings before and after migration. Pipeline specs still accept deprecated per-task defaults with a warning.

Migrate session write-back ​

CalibService(persist_output_parameters=...) is removed. Set update_calibration_parameters=False on every call that must remain measurement-only; unset calls write back by default. A custom step passes the setting in each session.execute_task(..., parameters={"update_calibration_parameters": False}) call. See output persistence for single-task APIs.

Testing ​

Run task test-workflow. Propagation tests are in tests/qdash/workflow/service/test_task_call_propagation.py; flow-parameter tests are in tests/qdash/workflow/test_task_call_flow_parameters.py.

Implementation Files ​

  • src/qdash/datamodel/task_call.py: identity and normalization
  • src/qdash/datamodel/task_settings.py: settings
  • src/qdash/workflow/service/_internal/call_runner.py: execution
  • src/qdash/workflow/service/steps/filters.py: result selection
  • src/qdash/workflow/engine/task/snapshot_loader.py: snapshot matching

Released under the Apache 2.0 License.